Welfare facilities on construction sites
Contents |
[edit] Introduction
There is a legal duty under The Workplace (Health, Safety and Welfare) Regulations 1992, as amended by The Construction (Design and Management) Regulations (CDM Regulations) to ensure that appropriate and adequate welfare facilities are provided at most workplaces.
The provision of welfare facilities should be considered at the planning stages of a project to ensure they are appropriately located.
The CDM regulations require that contractors, as far as is reasonably practicable, provide welfare facilities which meet the minimum requirements set out in Schedule 2 of the regulations for their own employees working on site or anyone else working under their control.
On projects where there is more than one contractor, the client and the principal contractor have a similar duty to ensure suitable and sufficient welfare facilities are provided for before any construction work starts and for the duration of the construction work. The principal contractor should liaise with other contractors involved in the project to ensure appropriate welfare facilities are provided. This should continue throughout the construction phase to take account of any changes which might change the requirement for the provision of welfare facilities.
Schedule 2 of the regulations suggests that the minimum welfare facilities required includes:
- Sanitary conveniences
- Washing facilities
- Drinking water
- Changing rooms and lockers
- Facilities for rest.
[edit] Sanitary conveniences
Clean and tidy toilets (sanitary conveniences) should be provided at easily accessible locations. They should have adequate ventilation and lighting. Ideally, separate male and female toilets should be provided but if this is not possible, as a minimum, rooms with lockable doors are required.
[edit] Washing facilities
Clean and tidy washing facilities with sufficient ventilation and lighting are required next to both toilets and changing areas with the following:
- Hot and cold running water.
- Soap or other cleaning agents.
- Towels or another method for drying hands.
- Showers may be required depending on the nature of the works.
Ideally, separate male and female facilities should be provided but if this is not possible, as a minimum, rooms with lockable doors are required.
[edit] Drinking water
An adequate supply of suitably signed drinking water is required, with suitable cups or other drinking vessels, unless the supply of drinking water is in a jet from which can be drunk easily.
[edit] Changing rooms and lockers
If employees are required to change into specialist clothing, separate male and female changing facilities are required with seating and secure areas for storing personal clothing and protective clothing. In addition facilities for drying wet clothing are required.
[edit] Rest facilities
Adequately heated rest facilities with the appropriate number of seats and tables are required, along with a method for heating drinks and warming food. Where necessary, they should include suitable facilities for a pregnant woman or a nursing mother to rest lying down.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
CIOB launches global mental health survey
To address the silent mental health crisis in construction.
New categories in sustainability, health and safety, and emerging talent.
Key takeaways from the BSRIA Briefing 2024
Not just waiting for Net Zero, but driving it.
The ISO answer to what is a digital twin
Talking about digital twins in a more consistent manner.
Top tips and risks to look out for.
New Code of Practice for fire and escape door hardware
Published by GAI and DHF.
Retrofit of Buildings, a CIOB Technical Publication
Pertinent technical issues, retrofit measures and the roles involved.
New alliance will tackle skills shortage in greater Manchester
The pioneering Electrotechnical Training and Careers Alliance.
Drone data at the edge: three steps to better AI insights
Offering greater accuracy and quicker access to insights.
From fit-out to higher-risk buildings.
Heritage conservation in Calgary
The triple bottom line.
College of West Anglia apprentice wins SkillELECTRIC gold.
Scottish government launch delivery plan
To strengthen planning and tackle the housing emergency.
How people react in ways which tend to restore their comfort.
Comfort is a crucial missing piece of the puzzle.
ECA launches Recharging Electrical Skills Charter in Wales
Best solutions for the industry and electrical skills in Wales.
New homebuilding skills hub launch and industry response
Working with CITB and NHBC to launch fast track training.